AST RESEARCH TECHNICAL BULLETIN TB-0025 7-9-84 PCNET II TERMINATOR ALTERNATIVE At times it may be desirable to move nodes (network workstations) to different locations along the trunk cable. If a terminated node (jumper block T in position 2) is exchanged for a non- terminated node (jumper block T in position 1) both PCs would have to be opened to change these jumpers. The alternative is to terminate the ends of the trunk cable and leave all the PCNet II boards non-terminating. The termination must be done at the two very end tap boxes using a 120 ohm resistor wired as seen in figure 1. Type and wattage of the resistor is not important although larger wattage resistors may not fit inside the tap box. The resistors are not supplied by AST, but are available from most electronic part suppliers. NOTE: As a portion of the data is in pictorial form, it is not included here. To obtain a complete copy of this technical bulletin, contact: AST RESEARCH, INC. 2121 Alton Avenue Irvine, California 92714 ATTENTION: Product Support (Technical Bulletin)