AST RESEARCH TECHNICAL BULLETIN TB-0278A 08/28/87 RAMPAGE 286 AST customers have reported some difficulties when using the Rampage 286 product. The symptoms occur when the Rampage 286 is being used to fill in conventional memory (below 640K). The actual symptoms are that data is being corrupted during a DMA transfer. This most commonly happens during a copy or back-up type operation. Rampage 286 boards that may exhibit this tendency can be identified by part number "202154-301" revision level "X1". These numbers are located on the circuit side of the board, along the edge of the board on the end opposite the mounting bracket. Observe the circuit side of the board and verify if there is a jumper wire connected to lifted pin U111-19 (74LS245) to pin U76-9 (PLS153). This jumper should correct the problem. If the jumper is not installed and the above problem exists, contact AST Product Support for further instructions.