============================================================================= AST RESEARCH, INC. TECHNICAL BULLETIN #0657 01/17/91 ============================================================================= PC SUPPORT VERSION 2.0 Customers have experienced problems when trying to run PC Support version 2.0 (AS/400) running under DOS version 4.X. While running the ASTPCS.BAT file to initiate PC Support, the following errors may occur: 5118 5042 To resolve this problem customers should check the AS/400 for the device description. If the device description is the default, "5251 model 11", this must be changed to "5150 model 1".