============================================================================= AST RESEARCH, INC. TECHNICAL BULLETIN #0773 08-25-92 ============================================================================= 3COM COMPATIBILITY IN AST EISA SYSTEMS PROBLEM: There is a bus timing problem with 3COM's 3C507 Coax board previous to modification 11, revision B and on the 3C507 TP board modification 4, revision B. CAUSE: When 3COM 3C507 Coax and 3C507 TP network interface cards are installed in AST EISA based systems, the following symptoms will occur: - Intermittent lock ups - Unreliable performance - ABEND (NetWare) - Trap Errors (OS/2) SYSTEMS AFFECTED: 386 Tower EISA, 486 Tower EISA, Premium SE, Power Premium, and 486 Desktop EISA. SOLUTION: The following revisions must be installed to fix the problem: The 3C507 Coax board must be a modification 11 or higher and of revision B or higher. This information is located in the upper right hand column of the board and is displayed as follows: ASSY 6750-11 REV B The 3C507 TP board must be a modification 04 or higher and of revision B or higher. This information is located in the upper right hand column of the board and is displayed as follows: ASSY 7508-04 REV B Customers with the above problem should call 3COM's RMA department for an upgrade at (800) 876-3266.