CLARION CAL-1000CT/3000CT/5100CT/5200CT. NOTES: This unit has three NAMS. The ESN prefix is 140 decimal & 8C hex. Clarion: 213-327-9100 NAM programing: 1. Turn on power, new phones will display "Err 3", this is normal. 2. Within 10 seconds press CLR followed by * * 1 2 3 1 2 3 # #. 3. The phone will display a "0" if you have completed the above steps correctly. 4. Select the NAM you want to program by entering 1, 2 or 3. 5. Each of the nine programing steps below is accessed by pressing RCL N, where N is the step number. 6. Enter the new data for each location followed by the STO key. 7. Turn the power off to complete programing. PROGRAMING DATA: STEP# #OF DIGITS/RANGE DESCRIPTION 0 3 OR 4 DIGITS LOCK CODE 1 00000 - 99999 SYSTEM ID 2 1 OR 2 LOCAL USE MARK 3 0 OR 1 MIN MARK 4 10 DIGITS MIN (AREA CODE & PHONE NUMBER) 5 2 DIGITS STATION CLASS MARK 6 333 OR 334 INITIAL PAGING CHANNEL 7 2 DIGITS ACCESS OVERLOAD CLASS 8 0 OR 1 PREFERRED SYSTEM (1=A, 0=B) 9 2 DIGITS GROUP ID (10 FOR USA) LOCK: F 0. UNLOCK: Three or Four digit code. SYSTEM SELECT: F 4 then 4 to scroll, STO to store.